  • The SpeeTile system has 2 variants: the SpeeTile10 and the SpeeTile12 system.
  • View all products that are part of the SpeeTile system here.
  • The SpeeTile system is suitable as a primary heating source in an insulated space.
  • The SpeeTile system can be applied on concrete/sand cement, wood, and pressure-resistant insulation subfloors.
  • Various top layers can be applied over the SpeeTile system, such as PVC, cast flooring, tiles, laminate, parquet, linoleum, and more. The applicator prepares the subfloor for finishing.
  • The SpeeTile10 system consists of:
  • The total system height including SpeeTop starts at 15mm.
  • The pipe spacing (centre-to-centre) for the SpeeTube heating pipe is 75mm.
  • After pouring with SpeeTop, the floor is walkable after 4 hours.
  • After curing of the SpeeTop, a 7-day heat-up protocol must be performed.
  • View the heat output chart of the SpeeTile10 system here.
  • The SpeeTile12 system consists of:
    – Modular plastic mats (H=15mm).
    – SpeeTube heating pipe Ø12mm
  • The SpeeTile12 system must be finished with, for example, an anhydrite or sand cement screed. This must be carried out by a third party.
  • The pipe spacing (centre-to-centre) for the SpeeTube heating pipe is 100 mm
  • View the heat output chart of the SpeeTile12 system here.
  • View the specifications for SpeeTile10 Wall heating/cooling
  • View all products that are part of the SpeeTile system here.
  • The SpeeTile10 system consists of:
  • The radiant heat from wall heating reaches 4 to 5 metres.
  • The SpeeTile10 system is suitable as a primary heating source in an insulated space. Consider exterior walls and ensure sufficient m² of wall heating.
  • View theheat output chart of the SpeeTile10 system here.
  • The SpeeTile10 system must be mounted on a stable surface suitable for plastering. On wood/Fermacell boards, this can be done with drywall screws, and on masonry walls using the plug anchor integrated in each SpeeTile mat.
  • The system can be finished with plaster or clay. The total build-up height including the wall heating is approximately 20mm.
  • Consult your plasterer about whether the wall requires a primer in advance.
  • The SpeeTile wall heating system has been tested and certified by Knauf Germany.
  • View the specifications for SpeeTile10 Ceiling heating/cooling
  • View all products that are part of the SpeeTile system here.
  • The SpeeTile10 system consists of:
  • The SpeeTile10 system must be mounted on a stable surface suitable for plastering. On wooden boards/framing, this can be done with drywall screws; on hollow core slabs and concrete using certified plugs.
  • The SpeeTile10 system is suitable as a primary heating source in an insulated space.
  • View the heat output chart of the SpeeTile10 system here.
  • The system can be finished with plaster or clay. The total build-up height including the ceiling heating is approximately 20mm. The use of reinforcing mesh is required.
  • Consult your plasterer about whether the ceiling requires a primer in advance.
WARP Systems Icoon systeem grijs

SpeeTherm dry construction system

WARP Systems Icoon SpeeTwall DryFix

SpeeTwall DryFix and DryFix+

WARP Systems Icoon installeren grijs

Connection

  • With central heating boiler: the heating system must be connected to the boiler using a plastic manifold with pump unit. This includes a thermo/manometer, adjustable flow meters, and an energy-efficient A-Label Grundfos Alpha2 pump.
  • With district heating/central block heating: the heating system must be connected to the district heating system using a plastic manifold with pump unit and non-return valve. This includes a thermo/manometer, adjustable flow meters, and an energy-efficient A-Label Grundfos Alpha2 pump.
  • With heat pump LTH (Low Temperature Heating primary source <40°C): the heating system must be connected to the heat pump using a plastic manifold without pump (open plastic manifold). This is double-walled to reduce condensation during cooling.

The SpeeTube heating pipes Ø10 and Ø12mm are connected to the manifold using PushFit connectors.

  • PushFit connectors come in 3 types: single, double (splitter), and repair connectors. The connection fittings are ¾″ eurocone.
  • With the PushFit splitter, two pipe circuits can be connected to one manifold outlet. The lengths of these two circuits must be equal.
  • Pipe diameter for supply and return lines from the boiler or district heating system:
    • manifolds up to 7 circuits: minimum Ø15mm, connection ½″
    • manifolds with 8 circuits or more: minimum Ø20mm, connection ¾″
  • Pipe diameter for supply and return lines from the heat pump or LTH: consult and follow the advice of your heat pump supplier.
Note: WARP Systems does not connect the system to the primary heat source. This must be done by a certified plumber.
WARP Systems Icoon vloerverwarming grijs

Subfloor

For concrete, sand cement, or anhydrite subfloor:

  • For concrete, sand cement, or anhydrite subfloor:
  • Any irregularities or small dips are filled afterward with the SpeeTop levelling mortar.
  • The floor must be clean, grease-free, and dry. For concrete and sand cement: residual moisture < 3%, for anhydrite floors: < 0,3%.
  • Before installing the SpeeTile system, a primer must be applied. This neutralizes the absorbency of the subfloor and ensures adhesion of the SpeeTop levelling mortar to the substrate.

For wooden subfloors:

  • The subfloor must be flat and rigid.
  • Joints and gaps must be sealed.

Insulation

  • The insulation layer must have a minimum compressive strength of 250 kPa and be glued to the subfloor.
  • Joints and seams must be sealed watertight with tape.
  • The SpeeTile system must be fixed onto the insulation layer using SpeeTackers.

For other types of subfloors:

Contact us in case of other types or a combination of subfloors.

For concrete, sand cement, or anhydrite subfloors:

  • The subfloor must be completely flat and free of dips and irregularities. It does not need to be level.
  • The floor must be clean and dry. For concrete and sand cement: residual moisture < 3%, for anhydrite floors: < 0,3%.

For wooden subfloors:

  • The subfloor must be completely flat and free of dips and irregularities.
  • The subfloor does not need to be stable and/or level.

For other types of subfloors:

Please contact us for other types or combinations of subfloors.

WARP Systems Icoon installeren grijs

Installation

  • View the WARP Systems, installation manuals, assembly instruction videos on YouTube, and useful installation tools.
  • Rent a pipe reel for easier installation.
  • For the SpeeTile system, you can use our SpeeTop Application Support service.
  • Request a layout plan based on a floor plan. It shows the laying pattern and length per circuit of the SpeeTube heating pipe.
  • Use this layout plan request form to request a layout plan.
  • The SpeeTile system is finished with SpeeTop levelling mortar. For this, WARP Systems offers a pouring service.
  • Read the terms for the ‘SpeeTop Application Support’ service here.

A minimum of 3 people is required for pumping. You can hire 2 or more WARP Systems staff members. Pump rental must always be combined with at least one WARP Systems technician. This person operates the pump and applies the levelling mortar. The other persons fill the pump and deaerate the mortar with a spiked roller.

  • Our SpeeTeam starts at 7:00 AM at the indicated project location.
  • Areas where no system or mortar should be applied (e.g., crawl space hatch or kitchen) must be sealed watertight in advance using wood. Minimum batten height: 3cm.
  • A water connection is required with a minimum pressure of 2.5 bar and 12.5 l/min.
  • An electrical connection of 230 volts and 16 amps must be available.
  • If needed, arrange a parking exemption or permit and provide a copy.
  • Note: We do not connect the system to the primary heat source. This must be done by a certified plumber.
  • Note: We do not install heat foil and/or Jumpax Basic.
  • Read our full “Installation Terms and Conditions ” here.

We apply the lump sum conditions for orders placed from 03-04-2023 onward.

When you choose full-service* installation by WARP Systems, the final order price is determined after processing the most recent site visit, known as the lump sum**. Note: If you wish to make changes after the latest processed site visit, this is only possible through written agreement with WARP Systems. The agreed installation price may then change.

*Full-service means that WARP Systems supplies and installs the selected WARP system according to the agreed terms.

**More information about the lump sum can be found in the installation terms and conditions.

WARP Systems Icoon opstook grijs

Finishing

    • The SpeeTile10 system including SpeeTop levelling mortar has a total build-up height starting from 15mm.
    • After pouring with SpeeTop, the floor is walkable after 4 hours.
  • A 7-day commissioning protocol  must be followed after curing of the SpeeTop.
  • Various floor finishes can be applied over the SpeeTile system, such as PVC, cast flooring, tiles, laminate, parquet, linoleum, etc. The applicator prepares the subfloor for the finish.
  • The system can be finished with plaster or clay. The total build-up height including the heating is approximately 20mm.
  • Consult with your plasterer whether a primer is required beforehand.
  • Consult with your plasterer whether reinforcement mesh should be applied.
  • A 1.2mm heat-foil can be applied over the SpeeTherm15 system. This reduces contact noise by 24% and is suitable for underfloor heating. Simply roll the heat foil over the SpeeTherm system, with the grey perforated foam layer facing up.
  • After placing the underfloor heating system, the floating final floor can be installed immediately.
  • Rigid, floating (non-glued) finishes such as laminate, engineered wood, Duoplank, etc. can be installed on the SpeeTherm15 system.
  • For flexible, non-rigid finishes such as click PVC, glued PVC, linoleum, or marmoleum, a pressure-distributing intermediate layer like
    WARP Systems Icoon opstook grijs

    Commissioning protocol

  • No drying times are required for the SpeeTherm system.
  • First install the floating, rigid final floor.
  • Then commission the underfloor heating system.
  • Follow the instructions and guidelines of the floor supplier.

Control and regulation technology

What is control and regulation technology for underfloor heating?
A control and regulation system ensures that each zone’s temperature is automatically maintained. The system drives the underfloor heating efficiently through, thermostats, a control centre (CC) and actuators on the manifold.

Which components make up WARP Systems’ zone control system?

What is the difference between the wired and wireless control?
With a wired system, the thermostats are connected to the Control Centre via cables. With a wireless system, the thermostats communicate via a Zigbee signal.

Can I combine the system with radiators?
Yes. You can connect a radiator thermostat to your radiator (requires an M30 thermostatic valve connection; adapters available separately). For more information, please contact our sales team.

Can I add extra zones to the system later?
Yes. Both the H64 and H128 systems are modular and can be expanded with additional thermostats and actuators, provided the underfloor heating is set up to support them.

Is it possible to control multiple manifolds with one system?
Yes. Depending on the system, multiple Control Centres can be linked together (in a master/slave cascade), with each manifold serving its own zone group(s).

New build
Both control systems (wired and wireless) can be used in a new-build home.

Existing construction
The most suitable system for existing homes is our H128 wireless system. No wiring is required except from the primary heat source to the first Control Centre.

Are the thermostats compatible with other brands?
The thermostats work only with the H64 or H128 Control Centre.

Can I control the system remotely?
Yes. By downloading the Heatlink app you can operate the system via your smartphone or tablet.

Can I set the schedule per zone in the app?
Yes. You can configure a separate weekly schedule for each room (zone) via the app.

Does the system work without internet?
Yes. The local control (room thermostats) continues to function offline. App control, however, requires the Gateway to be connected to the internet.

Can I set the temperature individually for each room?
Yes. The system supports zonal control by room. Any room equipped with a thermostat is managed as its own zone, even if you still have radiators in some spaces. You simply install a radiator thermostat on the radiator’s valve. Circulation areas are also heated via the piping that transports heat to the various zones.

How quickly does the system respond to temperature changes?
The actual temperature is measured continuously. When a deviation from the set temperature is detected, the actuators are automatically driven. They have a delayed reaction time of between 2 and 5 minutes.

Can I install the system myself?
Yes. Both the wired and wireless variants are designed for DIY installation.

How do I mount the actuators?
Screw the actuators directly onto the manifold’s return valves (standard M30×1.5). Then connect their pre-wired cables to the Control Centre. If you mount more than two actuators per zone, group them using terminal blocks and connect them with a two-core wire to the zone inputs on the control centre. Note: You can install up to five actuators per zone input and a maximum of 64 actuators on one control centre.

What is the difference between NC (Normally Closed) and NO (Normally Open) actuators?
NC actuators are closed by default and open when signaled. NO actuators work the opposite way. WARP Systems supplies NC actuators as standard, so if power fails, the underfloor heating stops to protect the system.

What is the maximum load of the control centre?
The control centre can drive multiple actuators per zone within the specified power range (see technical manual).

How is the control and regulation system powered?
The Control Centre and Gateway are powered by mains electricity. The wireless thermostats operate on two AA batteries.

What power supply is required for the Gateway?
The Gateway uses the supplied 5V USB adapter, which must be connected to mains power.

How long do the batteries last in a wireless thermostat?
Batteries typically last 1–2 years, depending on brand, usage and ambient temperature.

My thermostat won’t connect. What can I do?
Check the batteries (for wireless thermostats), ensure the thermostat is within range of the Control Centre and verify that the correct pairing procedure was followed.

The app shows an error message. How do I fix it?
Close the app completely and restart it, check your Wi-Fi connection and restart the Gateway if necessary. Refer to the manual for specific error codes.

The heating stays on even though the thermostat is off. What now?
Verify that the actuator is installed correctly and is functioning. Ensure each zone is assigned properly. Finally, check whether the thermostat wire to the primary heat source is connected to the NC port instead of the NO port (or vice versa), depending on the required configuration. Consult your installer or plumber for guidance.

WARP Systems Icoon FAQ

Order Process

At WARP Systems, the ordering process works as follows:

  • Based on your request, you will receive an email with a quotation. The quote includes the items, quantities, price, optional items, and payment and delivery terms.
  • If you agree with the quotation, confirm by replying to the email containing the offer. Please also state your desired delivery date, delivery address, and any optional items you wish to add.
  • The Sales department will send you an order confirmation email including the agreed final delivery date.
  • For self-installation, the order confirmation will include a deadline for any changes to your order. This date is set 8 days prior to the agreed delivery date.
  • If you want a layout plan with your self-installation, make sure to request it well in advance of the final delivery date so any adjustments can still be made to your order in time.
  • Check the order confirmation and return the signed version to us by replying to the email.
  • 2 days before delivery, your order will be prepared in our warehouse.
  • 1 day before delivery, your order will be picked up by the external carrier for delivery on the agreed date.
  • Upon delivery, you will receive a packing slip listing the delivered materials.
  • On the day of delivery, you will receive the invoice for the remaining amount due.
  • You pay the invoice within the agreed payment term.

For private individuals:

  • A 50% deposit is required upon confirmation of the order.
  • The balance is due within 7 working days after delivery.

For professionals:

  • For my first order, I pay the full order value in advance. Upon confirmation, I pay 50%, and no later than 4 working days before delivery, I pay the remaining 50%. (If there are fewer than 4 working days between confirmation and delivery, I pay the full order value in advance.)
  • For my second order, I pay 50% upon confirmation. The remaining 50% is paid no later than 7 days after the invoice date**.
  • For my third order, I pay the full invoice amount no later than 7 days after the invoice date.

If I, as a B2B customer, place another order with WARP Systems after more than 6 months, WARP Systems may request full prepayment for that next order due to possible changes in my circumstances. WARP Systems may also request full prepayment if I have received a payment reminder under any circumstance.

Order(s): refers to the purchase and optional installation of a complete WARP System (SpeeTile10/SpeeTile12/SpeeTherm15/SpeeTherm30). An assignment that does not include a complete WARP System is considered a product order only.

**Invoice date: the date shown on the issued invoice.

WARP Systems Icoon euro

General Terms and Guarantees

For private customers:

  • 50% deposit upon confirmation of the order.
  • Remaining 50% due within 7 working days after delivery.

For professionals:

  • For my first order, I pay the full order value in advance. Upon confirmation, I pay 50%, and no later than 4 working days before delivery, the remaining 50%. (If there are fewer than 4 working days between confirmation and delivery, I pay the full amount in advance.)
  • For my second order, I pay 50% upon confirmation. The remaining 50% is due no later than 7 days after the invoice date**.
  • For my third order, I pay the full invoice amount no later than 7 days after the invoice date.

If I, as a B2B customer, place a new order after 6 months, WARP Systems may require full prepayment for that next order due to possible changes in my financial position. WARP Systems may also require this if I have ever received a payment reminder.

*Order(s): refers to the supply, and any installation, of a complete WARP System (SpeeTile10 / SpeeTile12 / SpeeTherm15 / SpeeTherm30). An order that does not include a complete system is considered a product order only.

**Invoice date: the date listed on the issued invoice.

WARP Systems applies the Metaalunie warranty periods and general delivery terms.

Additional warranty periods:

  • Steel professional manifold: 5-year warranty on housing and 2-year warranty on pump and fittings.
  • Open plastic manifold: 10-year warranty on housing and 2-year warranty on fittings.
  • The SpeeTube heating pipe is KOMO and SKZ certified with a 30-year warranty.
WARP Systems Icoon FAQ

Delivery and Returns

  • Shipped within one working day.*
    * Orders placed and paid on weekdays before 12:00 are shipped the same day.
    * Custom manifolds available on request.
  • Installation scheduling is dynamic; please contact us for details.

Pallet transport:

  • Provide the correct phone number and email address for the recipient if different from the purchaser. This is used for Track&Trace and for delivery calls.
  • You can track your order with a Track&Trace code you’ll receive on the delivery day.
  • Pallet shipments are handled by an external transport company.
  • Your order is delivered on pallets up to 1 metre from the truck on weekdays between 08:00 and 17:00 by default.
  • Timed deliveries and tail-lift deliveries can be arranged with a three-working-day lead time at an additional cost. The same applies to the Wadden Islands and Zeeuws-Vlaanderen.
  • The pallets are deposit-free, store materials safely and dry.

Parcel delivery:

  • Parcel shipments are handled by PostNL, can be tracked via Track&Trace and are delivered Tuesday through Saturday.

 

  • Returns are only possible for products ordered from WARP Systems, in their original condition and undamaged packaging. Returns can be made up to 90 days after delivery.
  • Return shipping costs are the customer’s responsibility, or you can return free of charge to our warehouse in Nieuwveen.
  • Returned materials will be credited after receipt and inspection.
  • Please use the return form for all returns.
  • Before shipping, email a photo of the items to be returned along with the completed return form to (logistiek@warp-systems.nl).
  • Include the return form in the shipment and retain the Track & Trace code as proof of dispatch.
  • Return address: WARP Systems, Ampèrestraat 1A, 2441 LP Nieuwveen.

 

Return payment:

Once all invoices have been settled, the refund will be issued within 5 working days.

Mon-Fri: 08:00-17:00 uur

Shipping and Returns

View our delivery times and shipping options.

Terms and Conditions

Read all about our general terms and warranty policies.

Need extra help?

Is your question not listed? Need additional support with a specific issue? Then please contact us using the form below.

  • This field is for validation purposes and should be left unchanged.

WARP Systems for all your questions

Receive tailored advice and pricing, based on your unique situation.

vrouw met headset
9.1

Customer rating!

Known from
Radio and TV!

Hi! Mocht je ergens niet uitkomen kan je hier je vragen stellen!